| Solar > Outdoor Lighting |
|
Solar Street Lighting Luminary | Solar Street Lighting Controller | Solar Street Lighting System
CFL Road Lighting Luminary: RLL 11 W / 22 W | RLL 36 W / 72 W |
|
CFL ROAD LIGHTING LUMINARY |
|
| RLL 11W/22W |
| |
Focusing on road lighting with minimum running cost, maximum reliability and adequate light, TeamSustain has designed a variety of road lighting luminaries.
RLL 11W/22W series road lighting luminaries are the best replacement for the presently used streetlight fittings of incandescent bulbs and fluorescent tubes. These can light up rural roads with adequate light at low voltage. The technical features of RLL 11W/22W series are unique and open up new dimensions in road lighting.
RLL 11W road lighting luminaries can be used to replace light fitting using 100W incandescent bulb and RLL 22W for 40W tube light fitting, with the same light output and a saving of around 50% energy. |
 |
| |
FEATURES
- Highly reliable electronic ballast
- Wide operating voltage range (90-270V)
- THD less than 20%
- High circuit power factor (>0.98)
- Constant light output throughout 90-270VAC
- Automatic dusk to dawn operation (optional)
- Compact, elegant and weather proof design (IP 53)
- Protections against lightning and over voltages
- Rust free fitting components
|
| |
| TECHNICAL SPECIFICATIONS |
| |
|
RLL 11W |
RLL 22W |
General |
Application |
Streets and pedestrian lighting |
Use |
Outdoor |
Lamp type |
Compact Fluorescent Lamp (CFL), 4 Pin, Single U |
Lamp wattage |
11W |
22W(2 Nos of 11W) |
Rated light output (Lumens) |
900 ± 5% |
1800 ± 5% |
Electrical |
Normal working voltage |
230V AC |
Working voltage range |
90 to 270V AC |
Invert type |
Quasi sine wave, free running |
Inverter frequency |
25-30 kHz |
| Power consumption |
13.0 ± 1W |
23.5 ± 1.7W |
Lamp starting |
Soft start with pre-heating |
Current THD (up to 10th) |
<20% |
<12% |
Power factor |
>0.98 |
Protections |
Input surges and lamp end of life |
Junction box |
With 1A replaceable glass cartridge fuse |
Mechanical |
Fixing |
Pole mounting with mounting brackets, CF Lamp in base up configuration |
Connecting cable entry |
2mm2 twin code dual sheathed wire |
Canopy |
Injection moulded engineering plastic (IP53) |
Bowl |
UV stabilized, Non yellowing Acrylic |
Reflector |
Highly reflective anodised aluminum |
Color (canopy) |
Black |
Size (Shipping) (mm) |
410x150x110 |
410x150x110 |
Weight (Shipping) |
995gm |
1.13Kg |
|
| Note: Specifications subject to change without notice. Check for latest update |
| |
ORDERING INFORMATION |
| |
|
RLL 11W & 22W |
Model |
Wattage |
Number of Lamps |
Operation |
Suggested to Replace |
RLL-11AC1C |
11W |
1 |
Manual |
100 W Incandescent bulb |
RLL-11AC2C |
11W |
1 |
Automatic |
100 W Incandescent bulb |
RLL-22AC1C |
22W |
2 |
Manual |
40W Fluorescent tube |
RLL-22AC2C |
22W |
2 |
Automatic |
40W Fluorescent tube |
|
| |
|